Emergency Organisation: Alarms, Musters and Drills
SafetyHow a ship organises itself for any emergency: initial action, FORDEC and muster teams, the general emergency alarm (7 short + 1 long), the muster list and the drill rules of SOLAS III/19 and MGN 71. The alarm signal and drill frequencies come up in almost every MCA oral.
Last reviewed 1 Nov 2026 · From a professional captain's years of study notes · Organised with AI and checked against current regulations · How we write
On this page (10)
Three steps: initial action, FORDEC, team action
In short: Read first: nothing — this is the first topic of the Safety & Emergencies area. Next: Fire Triangle, Classes of Fire and Portable Extinguishers. Every emergency follows the same three steps: 1. initial action → 2. subsequent action (think with FORDEC, follow the ISM checklists) → 3. split the work between the muster teams.
- 1. Initial action comes from situational awareness: in the first seconds, know where you are and make the ship and people safe — position, depth, traffic, a safe place to be. Raise the alarm and call the Master.
- 2. Subsequent action: once the first moves are made, slow down and decide with FORDEC, then work through the ship’s emergency checklists from the Safety Management System (emergency preparedness is ISM Code 8).
- 3. Team action: the muster list gives each team its job, so people act at once without waiting for orders (next section).
FORDEC: a decision tool under pressure
- F — Facts: what is happening? Gather the information.
- O — Options: what could we do?
- R — Risks (and benefits) of each option.
- D — Decision: choose the best course of action.
- E — Execution: carry it out, give clear orders.
- C — Check: watch the result and adjust; go round again if needed.
- FORDEC comes from aviation, where pilots use it to reach clear, logical decisions in an emergency. It works the same way on the bridge.
On the bridge: fire alarm at 0300
- Initial action: check the detector panel, sound the general alarm, call the Master, note the time and position, make sure the ship is safe where she is (sea room, traffic, depth).
- Subsequent action: the Master takes the con and runs FORDEC — facts from the emergency team, options (fight the fire, close boundaries, call for help), risks, decision; the fire checklist is followed step by step.
- Team action: the bridge team keeps the ship safe and talks to the world; the emergency team goes to the fire; engine room gives pumps and power; interior/medical team counts people and prepares first aid.
Muster teams: who does what
In short: On the alarm the crew splits into four teams: Bridge, Deck / Emergency, Engine room / Back-up and Interior / Medical. Each person’s team and duty is written on the muster list.
- Bridge team: manoeuvre (helm, speed, position) · communications (internal, VHF, PA) · GMDSS (alerts and distress messages — see Distress Signals) · log and reporting · keeping the checklists in order, so no step is missed.
- Deck / Emergency team: the first-response party. It musters dressed and equipped, ready to commence (attack the fire, search, close openings) on the Master’s order.
- Engine room / Back-up team: machinery, fire pumps, power, ventilation and fuel shut-offs; backs up the emergency team and relieves it.
- Interior / Medical team: passenger and guest control, head count, first aid and casualty care — see Emergency Response, Radio Medical Advice and Medical Records.
- On a small yacht one person may cover several jobs; the idea stays the same: every job has a name next to it.
The general emergency alarm
In short: The general emergency alarm is seven or more short blasts followed by one long blast (• • • • • • • —) on the ship’s whistle or siren, plus a bell, klaxon or similar system where fitted (MGN 71 (M+F) Amd 1, 4.1). It calls everyone to muster. It is not the order to abandon ship.
- Sounded on the ship’s whistle or siren and, where fitted, an electrically operated bell or klaxon. In the UK the bell/klaxon is also required on certain ship classes of 45.7 m and over (SI 1999/2722, reg. 6(1)).
- It must be operable from the navigation bridge and (except the whistle) from other strategic points, and be audible throughout the accommodation and normal crew spaces (SI 1999/2722, reg. 6(2)).
- Once started it keeps sounding until switched off by hand; it may be interrupted briefly for a PA announcement (SI 1999/2722, reg. 6(3)).
- What it means: go to your muster station and start your muster-list duty. Passengers must be told it is a summons, not an abandon-ship order (MGN 71 (M+F) Amd 1, 5.6).
- Cargo ships may use the fire alarm to summon the crew, together with the whistle or siren signal (MGN 71 (M+F) Amd 1, 4.2). So some ships have no separate general alarm, but every ship has a fire alarm.
- For small craft, a common rule of thumb is that a general alarm is expected with more than 16 people on board or more than 750 kW of power — check the code that applies to your vessel.
- Abandon ship is ordered by the Master, by a signal or by word of mouth, at the Master’s discretion. The order must reach and be understood by everyone, including emergency parties far from the muster station (MGN 71 (M+F) Amd 1, 4.5).
- Every signal used must be described in the muster list and in the crew and passenger instructions (MGN 71 (M+F) Amd 1, 4.6).
Muster list and emergency instructions
In short: The muster list says who does what, where, on every alarm. Ships on international voyages must have one; the Master keeps it up to date and copies are posted in conspicuous places (MGN 71 (M+F) Amd 1, 2.1). Every cabin gets an emergency instruction card.
Muster list
- Who needs one: ships engaged on international voyages, and UK passenger ships of Classes II(A) and III (MGN 71 (M+F) Amd 1, 2.1).
- Who is responsible: the Master — prepares it, keeps it up to date and makes sure copies are exhibited (2.1).
- Approval: the MCA approves the format; MGN 71 says this for passenger ships of Classes I, II, II(A) and III (2.1).
- Language: MGN 71 asks for the language or languages of the people on board (2.1). In practice it is written in the ship’s working language, with English added.
- Contents:
- the general emergency alarm and other signals, and the action crew and passengers take on each (2.3);
- how the abandon-ship order is given;
- each person’s emergency duty (ideally one duty each, 2.4) and named substitutes for key people (2.5);
- survival craft assignments and the person in charge of each (2.6–2.7);
- the officer responsible for maintaining the life-saving and fire-fighting appliances (2.9);
- on passenger ships: duties for warning, assembling and controlling passengers and checking their lifejackets, and the assembly stations (2.3, 2.10).
Emergency instructions
- Crew: each crew member gets clear instructions in a language they understand — muster station, duties, allocated lifeboat or liferaft (MGN 71 (M+F) Amd 1, 3.1).
- Passengers and guests: an instruction card showing the general emergency alarm, displayed in every cabin, at muster stations and in other passenger spaces; illustrated where possible, and showing how to put on a lifejacket (3.2).
How often: the drill rules
In short: Every crew member takes part in at least one abandon-ship drill and one fire drill every month. If more than 25% of the crew missed last month’s drills on board, hold the drills within 24 h of leaving port (SOLAS III/19.3.2; MGN 71 (M+F) Amd 1, 5.2).
- Monthly: one abandon-ship + one fire drill per crew member (SOLAS III/19.3.2).
- 24 h / 25% rule: more than 25% of the crew did not take part in drills on board that ship in the previous month → drills within 24 h of leaving port. If full drills are not practical, hold at least a muster and instructions in that time (MGN 71 (M+F) Amd 1, 5.2). Holding the drill before sailing also meets the rule.
- Passenger ships (Classes I, II, II(A), III): an abandon-ship drill and a fire drill every week (MGN 71 (M+F) Amd 1, 5.3).
- Passenger muster: where passengers stay on board more than 24 h, muster them on departure and show them how to don a lifejacket (MGN 71 (M+F) Amd 1, 5.4).
- Enclosed space entry and rescue drills: crew with these duties drill at least every 2 months (SOLAS III/19, in force 1 January 2015).
- Lifeboats: launched with their crew and manoeuvred in the water at least every 3 months; free-fall lifeboats at least every 6 months (MGN 71 (M+F) Amd 1, 10.1, 10.4).
- Rescue boats: launched each month where possible, never more than 3 months apart (MGN 71 (M+F) Amd 1, 11.1).
- Other emergency drills (collision, flooding, MOB…) can replace or add to fire drills, as long as each person still does one fire drill a month (5.1). When planning drills, take the Code of Safe Working Practices into account (5.1): include, if possible, enclosed space entry, working aloft and rescue from dangerous places.
- MGN 71 (M+F) Amendment 1 (24 April 2025) replaced the original MGN 71: formatting and references only, no change of policy.
Running abandon-ship and fire drills
In short: Run every drill as if it were real (MGN 71 (M+F) Amd 1, 7.1). An abandon-ship drill starts with the general alarm and the muster; a fire drill assumes a fire somewhere different each time.
Abandon-ship drill
- Sound the general alarm (7 short + 1 long).
- Stage one — muster: everyone to muster stations; crew clear unused spaces, marshal passengers, check lifejackets are worn correctly; child lifejackets for anyone under 32 kg (MGN 71 (M+F) Amd 1, 5.1, 6.1).
- Everyone must know the abandon-ship signal or order.
- Stage two — survival craft stations: lifeboat engines run ahead and astern for at least 3 min, liferaft davits swung out and winches worked, emergency lighting tested (MGN 71 (M+F) Amd 1, 9.3–9.5).
- Lifejackets are worn at musters and drills; crew in a fire drill may take them off (5.7).
Fire drill
- Conduct it, as far as practicable, as a real emergency (MGN 71 (M+F) Amd 1, 7.1).
- It is often run together with the first stage (the muster) of the abandon-ship drill.
- Assume a fire in a part of the ship and vary the place and type over time: machinery space, accommodation, galley, cargo, oil/gas (7.3).
- Start the fire pumps, get full pressure on the fire main, lay out the hoses (7.4).
- Practise closing doors, scuttles, ventilation and fire doors (7.5).
- Test the fixed extinguishing systems and alarms; use breathing apparatus, in pairs where possible (7.6).
- Discharge at least one extinguisher per drill, by a different crew member each time (7.8).
Fire equipment checks and drill records
In short: Fire equipment is checked on a monthly, quarterly and annual cycle (MGN 71 (M+F) Amd 1, 7.12). Every drill goes in the official log book (MGN 71 (M+F) Amd 1, 16.1).
| Cycle | What to check |
|---|---|
| Monthly | All fire-fighting equipment in place · ship’s alarms · fire installation valves · sprinkler pump pressure and system pressure · fire pumps working |
| Quarterly | Portable extinguishers · automatic fire alarms · international shore connection · fire-equipment lockers hold a full inventory · fire doors and dampers operate |
| Annual | Fire doors operate remotely · foam and water systems work · all pumps work · hydrants operate · antifreeze where needed |
- Records: enter in the official log book the date, the type of drill or training, and every time a lifeboat, rescue boat or davit-launched liferaft is lowered or launched. If a muster, drill or training session was not held in full, record why and how much was done (MGN 71 (M+F) Amd 1, 16.1).
- A drill matrix (a table of every drill and its due date) helps the Master and the safety officer see at a glance what is due.
⚡ Flashcards
Test yourself, one card at a timeQ1What are the three steps of any emergency response?
Answer1. Initial action (situational awareness: position, safe place, raise the alarm) → 2. Subsequent action (FORDEC + ISM checklists) → 3. Split the work between the muster teams.
Common trapDon’t jump to the checklist before the ship is safe.
Q2What does FORDEC stand for?
AnswerFacts · Options · Risks (and benefits) · Decision · Execution · Check. Borrowed from aviation.
Common trapC = Check, not “Communicate”.
Q3Name the four muster teams and the bridge team's jobs.
AnswerBridge · Deck/Emergency · Engine room/Back-up · Interior/Medical. Bridge: manoeuvre, communications, GMDSS, log/reporting, checklists.
Q4What is the general emergency alarm, and what does it mean?
Answer7 or more short blasts + 1 long blast on whistle/siren (+ bell/klaxon) — MGN 71, 4.1. It means “go to your muster station”.
Common trapIt is not the order to abandon ship.
Q5How is the order to abandon ship given?
AnswerBy the Master, by signal or by word of mouth, at the Master’s discretion; it must reach everyone (MGN 71, 4.5).
Q6Who keeps the muster list, and what is on it?
AnswerThe Master keeps it up to date and posted. Alarm signals and actions, how abandon ship is ordered, each person’s duty and substitutes, survival craft, officer responsible for LSA and fire-fighting appliances (MGN 71, 2.1–2.9).
Q7How often does each crew member do abandon-ship and fire drills? What is the 24 h rule?
AnswerOne of each every month. More than 25% of the crew missed last month’s drills on board → drills within 24 h of leaving port (SOLAS III/19.3.2).
Common trapNot “24 h before departure” — within 24 h of leaving port (drilling before sailing also meets it).
Q8Enclosed space drills, lifeboat and rescue boat launching: how often?
AnswerEnclosed space entry and rescue: every 2 months (SOLAS III/19, since 1 Jan 2015). Lifeboat launched every 3 months; free-fall every 6 months; rescue boat monthly, max 3 months (MGN 71).
Q9What does a good fire drill include?
AnswerRun as real; fire assumed in a different place each time; fire pumps started, hoses out; doors, vents and fire doors closed; fixed systems and alarms tested; BA in pairs; one extinguisher discharged by a different person each time (MGN 71, 7).
Q10Give one monthly, one quarterly and one annual fire equipment check.
AnswerMonthly: fire pumps / alarms / sprinkler pressure. Quarterly: extinguishers / international shore connection / fire doors and dampers. Annual: fire doors by remote control / foam and water systems / hydrants (MGN 71, 7.12).
Q11What do you write in the log book after a drill?
AnswerDate, type of drill or training, boats or davit-launched liferafts lowered/launched; if not held in full, why and how much was done (MGN 71, 16.1).
📚 Resources
Videos
- Allure of the Seas Sounds General Alarm — SolarAndHydro (hear the 7 short + 1 long signal)
Regulations
- MGN 71 (M+F) Amendment 1: Musters, drills, on-board training and instructions, and decision support systems — MCA, 24 April 2025
- MGN 71 Amendment 1 — Annex — MCA (muster lists, alarm, drill frequencies, records)
- The Merchant Shipping (Musters, Training and Decision Support Systems) Regulations 1999, regulation 6 — general emergency alarm signal
- SOLAS III/8, III/19 and III/37 · LSA Code 7.2 · ISM Code 8
Further reading
- Mandatory drills for entry into enclosed spaces — Skuld P&I
- General emergency signal — Wikipedia
Exam focus — MCA
Typical questions • “What is the general alarm? What do you do when you hear it?” → 7 or more short + 1 long; go to your muster station and start your muster-list duty. It is not abandon ship. • “How is abandon ship ordered?” → by the Master, by signal or word of mouth. • “How often are drills held?” → each crew member one abandon-ship and one fire drill a month; within 24 h of leaving port if more than 25% missed last month (SOLAS III/19.3.2, MGN 71). Bonus: enclosed space every 2 months, lifeboat launch every 3 months. • “What is on the muster list and who is responsible?” → the Master; signals, duties, substitutes, survival craft, officer responsible for LSA and fire-fighting appliances. • “You’re the OOW and the fire alarm sounds — what do you do?” → initial action, call the Master, general alarm, muster teams, FORDEC. How to answer: give the number and the reference (SOLAS III/19, MGN 71) first, then one practical step on board. Examiners want to hear that the general alarm is a summons to muster, not an abandon-ship order.